<?xml version='1.0' encoding='UTF-8'?><?xml-stylesheet href="http://www.blogger.com/styles/atom.css" type="text/css"?><feed xmlns='http://www.w3.org/2005/Atom' xmlns:openSearch='http://a9.com/-/spec/opensearchrss/1.0/' xmlns:georss='http://www.georss.org/georss' xmlns:gd='http://schemas.google.com/g/2005' xmlns:thr='http://purl.org/syndication/thread/1.0'><id>tag:blogger.com,1999:blog-6743586198611027924</id><updated>2011-11-27T15:44:39.639-08:00</updated><category term='energy audits'/><category term='switching heating fuels'/><category term='radiant floor heat'/><category term='indirect-fired water heater'/><category term='solar water heating'/><category term='commercial water heating sizing'/><category term='fuel conversion'/><category term='indirect-fired water heaters'/><category term='attic mold'/><category term='mixing valves'/><category term='sizing water heaters'/><category term='Rinnai'/><category term='central humidifiers'/><category term='in floor radiant heating'/><category term='condensing boiler problems'/><category term='hydronic radiant heat'/><category term='dual fuel heating system'/><category term='attic ventilation'/><category term='Triangle Tube Prestige'/><category term='energy efficient heating'/><category term='blower door test'/><category term='Bosch'/><category term='Viessmann Vitodens'/><category term='thermal solar'/><category term='munckin boiler'/><category term='Boilermate'/><category term='condensing boilers'/><category term='Takagi'/><category term='hydronics in-floor radiant heating'/><category term='heat pump'/><category term='tankless water heaters'/><category term='baxi boiler'/><category term='high oil prices'/><category term='switching to natural gas'/><title type='text'>Enhanced Living Blog</title><subtitle type='html'></subtitle><link rel='http://schemas.google.com/g/2005#feed' type='application/atom+xml' href='http://enhancedlivingblog.blogspot.com/feeds/posts/default'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/6743586198611027924/posts/default?max-results=100'/><link rel='alternate' type='text/html' href='http://enhancedlivingblog.blogspot.com/'/><link rel='hub' href='http://pubsubhubbub.appspot.com/'/><author><name>www.enhancedliving.net</name><uri>http://www.blogger.com/profile/15985241952228774254</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='19' height='32' src='http://bp1.blogger.com/_UCJi7Tzohac/SG58dAPxGkI/AAAAAAAAAAU/34fwqCcQtGQ/S220/John_CS.jpg'/></author><generator version='7.00' uri='http://www.blogger.com'>Blogger</generator><openSearch:totalResults>16</openSearch:totalResults><openSearch:startIndex>1</openSearch:startIndex><openSearch:itemsPerPage>100</openSearch:itemsPerPage><entry><id>tag:blogger.com,1999:blog-6743586198611027924.post-2006470138420925320</id><published>2009-08-02T18:48:00.000-07:00</published><updated>2009-08-02T19:26:50.799-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Viessmann Vitodens'/><category scheme='http://www.blogger.com/atom/ns#' term='condensing boilers'/><title type='text'>Viessmann Re-designs the Vitodens 200</title><content type='html'>Great news from our favorite friends in Allendorf, Germany.  Viessmann Manufacturing, the world leader in high-performance boilers, have re-designed their signature wall-hung condensing boiler, the Vitodens 200.  Not only have they improved the boiler, they've made the price more attractive, too. &lt;br /&gt;&lt;br /&gt;The two biggest changes are to the burner and the control system.  The previous version of the Vitodens 200 utilized a burner and gas-train provided by a third-party manufacturer.  The new Vitodens 200 now features a Viessmann-manufactured "Lambda" burner. &lt;br /&gt;&lt;br /&gt;The new "Lambda" burner offers ultra-clean combustion by contiuously monitoring and adjusting the fuel-to-air ratio.  The result is near-perfect combustion no matter the quality of the fuel, firing-rate of the boiler, or the ever-changing conditions within the combustion-chamber itself.  While we loved the previous matrix burner of the Vitodens 200, the new Lambda burner is a dream to service, allowing a tech to disassemble and re-install in a matter of seconds. &lt;br /&gt;&lt;br /&gt;The second major change is to the control system.  The previous version featured the "Comfortrol" control system, found only on the Vitodens 200.  The new version utilizes the same Vitotronic control platform used on their other boilers, such as the Vitola 200.  This gives the boiler greater flexibility in special situations where multiple motorized mixing-valves are required, or for staging multiple boilers.  It also allows for the use of the Vitotrol remote programming units and/or room sensors. &lt;br /&gt;&lt;br /&gt;In addition to the changes to the burner and control system, the jacket has been modernized and updated.  Viessmann also eliminated the separate domestic hot water connections  and diverting assembly, as well as the internal circulator.  These changes may be viewed as a negative by some, however, it has simplified the boiler mechanically, which means fewer moving parts and less chance for failure down the road.&lt;br /&gt;&lt;br /&gt;As a result of these changes, coupled with Viessmann's construction of a new, streamlined manufacturing facility, the price of the Vitodens 200 has been reduced by approximately 30 percent.  This is good news all the way around.  Can't way to install them this winter. &lt;br /&gt;&lt;br /&gt;To learn more about Viessmann boilers, visit &lt;a href="http://www.enhancedliving.net/"&gt;www.enhancedliving.net&lt;/a&gt;.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/6743586198611027924-2006470138420925320?l=enhancedlivingblog.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://enhancedlivingblog.blogspot.com/feeds/2006470138420925320/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=6743586198611027924&amp;postID=2006470138420925320' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/6743586198611027924/posts/default/2006470138420925320'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/6743586198611027924/posts/default/2006470138420925320'/><link rel='alternate' type='text/html' href='http://enhancedlivingblog.blogspot.com/2009/08/viessmann-re-designs-vitodens-200.html' title='Viessmann Re-designs the Vitodens 200'/><author><name>www.enhancedliving.net</name><uri>http://www.blogger.com/profile/15985241952228774254</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='19' height='32' src='http://bp1.blogger.com/_UCJi7Tzohac/SG58dAPxGkI/AAAAAAAAAAU/34fwqCcQtGQ/S220/John_CS.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-6743586198611027924.post-529903521843692725</id><published>2009-07-23T12:36:00.000-07:00</published><updated>2009-07-23T13:00:08.733-07:00</updated><title type='text'>Overstock heating equipment -- act fast, save big!</title><content type='html'>Thanks to our longstanding relationship with local HVAC wholesalers, we have exclusive access to a limited number of boilers, warm air furnaces, water heaters and air conditioning units, which are being sold to us at &lt;u&gt;below wholesale cost&lt;/u&gt;.&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;Because we save at the wholesale leverl, we can pass these dep discounts on to you.  &lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;&lt;/strong&gt;&lt;br /&gt;By choosing to replace your outdated heating or cooling equipment now rather than later, &lt;em&gt;you stand to save up to $2,000 on a new system installation.&lt;/em&gt; &lt;br /&gt;&lt;br /&gt;&lt;em&gt;Why so cheap?  &lt;/em&gt;The slow economy has left wholesale suppliers with excess inventory, especially big-ticket items like boilers, furnaces, water heaters and air conditioning systems.  Rather than take up valuable warehouse space or risk damage, our suppliers are willing to sell their overstock at or below &lt;em&gt;their&lt;/em&gt; cost.  Available equipment includes high quality brands with factory-backed warranties. &lt;br /&gt;&lt;br /&gt;So, if you're worried about getting through one more winter on an aging boiler or furnace, or want to spend the summer in the luxury of air conditioning, now's the time to buy!&lt;br /&gt;&lt;br /&gt;Just remember, once it's gone, it's gone!&lt;br /&gt;&lt;br /&gt;Below is a sample of available of what's available.  For a cost estimate on installation, please &lt;a href="mailto:info@enhancedliving.net"&gt;e-mail&lt;/a&gt; or call (518) 235-0311.&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;&lt;u&gt;Boilers&lt;/u&gt;:&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;&lt;/strong&gt;&lt;br /&gt;New Yorker CLW-5 oil-fired boiler (148,000 or 189,000 btu)&lt;br /&gt;New Yorker PVCG Direct-vent boiler for LP gas (107,000 btu)&lt;br /&gt;Burnham Direct-vent boiler for LP gas (140,000)&lt;br /&gt;&lt;br /&gt;&lt;u&gt;&lt;strong&gt;Warm air furnaces:&lt;/strong&gt;&lt;/u&gt;&lt;br /&gt;&lt;strong&gt;&lt;u&gt;&lt;/u&gt;&lt;/strong&gt;&lt;br /&gt;TempStar 106,000 btu oil-fired furnace&lt;br /&gt;TempStar 80+ AFUE furnace for natural gas (100,000 btu)&lt;br /&gt;TempStar 80+ 2-stage furnace for natural gas ( 75,000 btu)&lt;br /&gt;TempStar 95 AFUE gas furnace (60,000 btu)&lt;br /&gt;Coleman oil-fired mobile home furnace (66,000 btu)&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;&lt;u&gt;Air conditioning&lt;/u&gt;:&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;&lt;/strong&gt;&lt;br /&gt;Comfort Air 18,000 btu ductless mini-split&lt;br /&gt;EMI 12,000 btu ceiling mount ductless mini-split&lt;br /&gt;Comfort Air 24,000 2-zone ductless mini-split&lt;br /&gt;ECW 9,000 btu ductless mini-split&lt;br /&gt;ECW 12,000 btu ductless mini-split&lt;br /&gt;&lt;strong&gt;&lt;u&gt;&lt;/u&gt;&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;&lt;u&gt;Water heaters&lt;/u&gt;:&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;&lt;/strong&gt;&lt;br /&gt;(2) Rinnai tankless water heater for LP (2532FFUC-P)&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;This is just a sampling of available units.  Please &lt;a href="mailto:info@enhancedliving.net"&gt;e-mail&lt;/a&gt; us what you are looking for and we'll check on availability.  &lt;/strong&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/6743586198611027924-529903521843692725?l=enhancedlivingblog.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://enhancedlivingblog.blogspot.com/feeds/529903521843692725/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=6743586198611027924&amp;postID=529903521843692725' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/6743586198611027924/posts/default/529903521843692725'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/6743586198611027924/posts/default/529903521843692725'/><link rel='alternate' type='text/html' href='http://enhancedlivingblog.blogspot.com/2009/07/overstock-heating-equipment-act-fast.html' title='Overstock heating equipment -- act fast, save big!'/><author><name>www.enhancedliving.net</name><uri>http://www.blogger.com/profile/15985241952228774254</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='19' height='32' src='http://bp1.blogger.com/_UCJi7Tzohac/SG58dAPxGkI/AAAAAAAAAAU/34fwqCcQtGQ/S220/John_CS.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-6743586198611027924.post-763900920417312933</id><published>2009-01-11T08:46:00.000-08:00</published><updated>2009-01-11T11:18:04.443-08:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Viessmann Vitodens'/><category scheme='http://www.blogger.com/atom/ns#' term='Triangle Tube Prestige'/><category scheme='http://www.blogger.com/atom/ns#' term='baxi boiler'/><category scheme='http://www.blogger.com/atom/ns#' term='condensing boiler problems'/><category scheme='http://www.blogger.com/atom/ns#' term='munckin boiler'/><title type='text'>Condensing boiler problems (and their solutions)</title><content type='html'>If you've recently installed a new condensing boiler -- Baxi, Viessmann, Buderus, MZ, Munchkin, etc. -- and are experiencing problems, we can help.  As a "new" technology, condensing boilers require a special knowledge and new set of rules when it comes to piping and controls.&lt;br /&gt;&lt;br /&gt;Unfortunately, many "old school" plumbers and heating guys don't fully understand or appreciate the new piping and control methods that condensing boilers require in order to work effectively, efficiently and trouble-free.  As a result, many new condensing boiler installations are rife with problems -- frequent lock-outs and failures, excessive heating bills, over-heating and under-heating of rooms throughout the home, etc..&lt;br /&gt;&lt;br /&gt;While the list of symptoms are long and varied, most fall within one of three categories:  1)  piping problems, 2) under-control, and 3) poor commissioning. &lt;br /&gt;&lt;br /&gt;Let's start with the first category -- piping problems.  Conventional non-condensing boilers are a relatively simple affair.  When the thermostat calls for heat, the boiler turns on and gets hot (180 degrees +), hot water leaves the boiler, goes through the radiators, and comes back at about 160 degrees.  When the room is sufficiently heated, the boiler turns off.  The piping to accomplish this is also simple -- supply-piping out, return-piping in.  Done deal.&lt;br /&gt;&lt;br /&gt;Unlike their bigger, meatier non-condensing cousins, condensing boilers, by and large, are designed with smaller, narrower heat-exchangers.  As a result, there is a substantial "pressure-drop" through the boiler.  In condensing boilers, the heat-exchanger acts as a bottle-neck that gives standard circulator pumps a heck of a time pushing sufficient flow through both the boiler and the radiators it's connected to. &lt;br /&gt;&lt;br /&gt;Many installers fail to take this high pressure-drop into consideration when piping a new condensing boiler into an existing system.   The result of this oversight is often a house that becomes under-heated, particularly as the weather gets colder.&lt;br /&gt;&lt;br /&gt;The fix is simple -- read the boiler's installation manual!  Most, if not all, manufacturers provide detailed piping diagrams for their boilers.  And most, if not all, involve some form of "primary-secondary" piping and/or hydraulic separation.  The theory and practice of hydraulic separation is too much to get into hear, but to read more visit &lt;a href="http://www.caleffi.us/en_US/caleffi/Details/News/files/HydSep102508.pdf"&gt;here&lt;/a&gt;.       &lt;br /&gt;&lt;br /&gt;As an aside, homes with small heating loads, say, less than 70,000 btus, depending on the boiler, may not need hydraulic separation.  Because the load is small, the boiler pump can move enough btus, despite the bottle-neck, to heat the home sufficiently.  Also, homes with large diameter pipes (originally designed for an old, gravity-type system), can also often be heated without hydraulic separation, since the flow-rate requirements and pressure-drop through the pipes are usually very low.  For everyone else, hydraulic separation is the way you need to do it.&lt;br /&gt;&lt;br /&gt;The next category of problems results from under-control.  Condensing boilers are typically designed with modulating burners, which (theoretically) ramp up or down depending on heating conditions.  Most boilers have one or more mechanisms to tell the boiler when to step on or let off the gas, but the usual starting point is feedback from temperature-sensors within the boilers supply and return pipes.  When the temperature difference between supply and return increases, the boiler assumes more heat is need to the house and steps on the gas.  As the temperature difference decreases, it steps down. &lt;br /&gt;&lt;br /&gt;This is fine for many applications, but also has some shortcomings that, under certain conditions, can cause over-firing and/or short-cycling.  Some cheaper condensing boiler rely solely on boiler supply/return temperature-sensors to modulate the burner.  Higher quality, more sophisticated models, however, also utilize one or more forms of external feedback in the form of an outdoor-reset control and/or indoor temperature-feedback.  Such controls often convert outdoor or indoor temperature feedback into a 0-10vdc electrical signal that ramps the burner up and down depending on the weather outside or the indoor ambient temperature.  Such controls do a superior job at matching the boiler's output to the actual load of the home, and maximizes the boiler's efficiency.        &lt;br /&gt;&lt;br /&gt;Some boilers, like the Viessmann Vitodens 200, provide both outdoor-reset and indoor temperature feedback as a standard feature.  Other boiler manufacturers sometimes offer such features as an optional upgrade.  In these cases, unfortunately, many installers fail to inform homeowners of the importance of such controls and fail to integrate them into the home. &lt;br /&gt;&lt;br /&gt;Why are such controls so important?  They are often the main means by which the boiler actually condenses its flue-gases and provides combustion-efficiencies in the 90 percent + range.  In order for a boiler to actually condense, its flue-gases must drop below the magic number of 137 degrees fahrenheit (in natural gas-fired boilers).  In order to meet this target temperature, the boiler must produce lower than normal water temperatures, which, in turn, means it must lower its burner-output.  If, on the other hand, the boiler fails to maintain sub-137 degrees, its efficiency is only in the 85 percent ballpark at best.  Or, if it maintains low temperatures, but must run short cycles to do so, you add significant wear and tear on the boiler and in some cases may not be actually achieving high combustion efficiencies. &lt;br /&gt;&lt;br /&gt;The third category of problems often associated with condensing boilers is often due to poor commissioning practices by the installer.  Some condensing boilers are equipped with sophisticated computers.  That said, the computers are only as smart as the user and require some basic inputs by the installer that affect the modulation and control of the boiler.  Some installers fail to provide such inputs and allow the boiler to run off its default settings.  That result is a boiler that fails to operate at maximum efficiency. &lt;br /&gt;&lt;br /&gt;In other cases, some boilers require an initial adjustment to the boiler's modulating gas valve.  Failing to match the incoming gas pressure to the appropriate outputs (high and low fire) can result in over or under-firing and, short-cycling, or even outright malfunction and breakdown.  Proper commissioning is crucial to owning a happy condensing boiler. &lt;br /&gt;&lt;br /&gt;Finally, another often-seen problem with condensing boilers is the failure to properly match the boiler with the right distribution system (i.e. radiators, baseboard, etc.).  As efficient as condensing boilers can be, they're not always a good candidate for some homes, and aren't worth spending the premium to install.  Some homes, particularly those with finned-tube baseboard, require high boiler supply water temperatures to remain heated comfortably.  Since condensing boilers can't condense above 137 degrees, it doesn't make sense to employ one if the home's baseboards require higher temperatures.&lt;br /&gt;&lt;br /&gt;Now, if you're in a position where you've had a condensing boiler installed on a baseboard system and you have't noticed a significant drop in fuel bills,  you can always upgrade your standard-output baseboard to a "high-capacity" model and/or increase the length of it whereever feasible. &lt;br /&gt;&lt;br /&gt;Have a problem?  E-mail it to us by clicking &lt;a href="mailto:info@enhancedliving.net"&gt;here&lt;/a&gt;.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/6743586198611027924-763900920417312933?l=enhancedlivingblog.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://enhancedlivingblog.blogspot.com/feeds/763900920417312933/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=6743586198611027924&amp;postID=763900920417312933' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/6743586198611027924/posts/default/763900920417312933'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/6743586198611027924/posts/default/763900920417312933'/><link rel='alternate' type='text/html' href='http://enhancedlivingblog.blogspot.com/2009/01/condensing-boiler-problems-and-their.html' title='Condensing boiler problems (and their solutions)'/><author><name>www.enhancedliving.net</name><uri>http://www.blogger.com/profile/15985241952228774254</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='19' height='32' src='http://bp1.blogger.com/_UCJi7Tzohac/SG58dAPxGkI/AAAAAAAAAAU/34fwqCcQtGQ/S220/John_CS.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-6743586198611027924.post-3515703619550651303</id><published>2009-01-01T09:06:00.000-08:00</published><updated>2009-01-01T09:12:24.662-08:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='solar water heating'/><category scheme='http://www.blogger.com/atom/ns#' term='thermal solar'/><title type='text'>Thermal solar water heating design primer</title><content type='html'>With the re-authorization and expansion of federal tax credits for solar technologies, 2009 is expected to be a growth year for solar installations. With a much lower initial cost and faster pay-back than photo-voltaics, thermal solar systems (aka solar water-heating) will be of particular interest to architects and homeowners alike.&lt;br /&gt;&lt;br /&gt;In the realm of thermal solar systems, many options are available — from drain-back and closed-loop systems to a near infinite number of ways to configure and integrate into the existing space and water-heating infrastructure. Here’s a quick and dirty overview.&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;Drain-back vs. closed-loop&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;All thermal solar systems consist of collectors, either flat-plate type or vacuum-tube, usually mounted on the roof, an insulated storage tank, a pumping mechanism to transfer heat collected at the roof and move it to the storage tank, and piping filled with a water/anti-freeze solution used as the heat-carrying medium.&lt;br /&gt;&lt;br /&gt;In drain-back systems, the collectors have the ability to drain themselves of their water/anti-freeze solution in order to protect against freezing or over-heating (under certain conditions, collectors can exceed 212 degrees F). A small secondary reservoir tank is required to store the water/anti-freeze solution when not being used in the collectors. In addition, since drain-back systems are “open-loop,” a large, high-head pump is required to lift the solution from the reservoir tank into the collectors.&lt;br /&gt;&lt;br /&gt;Closed-loop systems have no such drain-back mechanism and rely on anti-freeze for wintertime protection; and sound engineering and system design to protect against over-heating. Mechanically simpler than drain-back systems, closed-loop configurations require no reservoir tank and only a small low-head pump to move the water/anti-freeze solution through the system.&lt;br /&gt;&lt;br /&gt;Our take: Reserve drain-back systems for special situations only (i.e. large commercial systems). For typical residential installations, closed-loop systems, with fewer moving parts, offer a simpler, less expensive and easier to maintain option for homeowners. Properly designed and maintained, closed-loop systems will not freeze and will not cause over-heating problems. Keep it simple!&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;Thermal solar for space-heating&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;The Catch-22 of thermal solar is that when you need the most heat, the sun produces the least energy. So, the question is whether it’s worth the additional expense and effort to integrate a thermal solar system with a home’s (hydronic) space-heating infrastructure.&lt;br /&gt;&lt;br /&gt;In upstate New York, for example, during the month of October a typical 30-tube collector array collects, on average, between 25,000 and 30,000 btus per day. In a modest home, this represents around 5 percent of the home’s total space-heating needs. In January, on the other hand, the same collector will produce less than 1 percent of the home’s space-heating needs.&lt;br /&gt;&lt;br /&gt;Yes, you can add more collectors to capture more heat, but that would require considerable amount of additional storage capacity — I mean considerable. There’s two problems to contend with. First, the collectors only produce heat during the day — when it’s the night you need the most heat. The second problem is the overabundance of heat you’ll be left with in the summer. Unless, you have an Olympic-size swimming pool to heat, you’ll have paid for equipment that heats water you can’t use.&lt;br /&gt;&lt;br /&gt;Our take: Integrating a thermal solar system into a home’s heating circuit adds at least $2,500 on the cost of installation, and increases its complexity and long-term maintenance. In the cold Northeast, we say spend the money elsewhere — upgrade insulation or improve the efficiency of the space-heating system.&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;Simple, cost-effective design&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;In thermal solar design, less is more. Keeping a system simple will shorten its pay-back and cost less to maintain over the long-term. With good, direct exposure to the sun, we recommend a modest three-panel array connected to a single-coil indirect-fired storage tank serving as a pre-heater to the home’s primary water heater. This configuration will produce approximately 75 percent of a home’s total annual domestic hot water load, uses the least moving parts, is a cinch to trouble-shoot and repair (one pump, one control device), and finds a perfect balance between maximizing the efficiency of the collectors at a relatively low installation cost.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/6743586198611027924-3515703619550651303?l=enhancedlivingblog.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://enhancedlivingblog.blogspot.com/feeds/3515703619550651303/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=6743586198611027924&amp;postID=3515703619550651303' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/6743586198611027924/posts/default/3515703619550651303'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/6743586198611027924/posts/default/3515703619550651303'/><link rel='alternate' type='text/html' href='http://enhancedlivingblog.blogspot.com/2009/01/thermal-solar-water-heating-design.html' title='Thermal solar water heating design primer'/><author><name>www.enhancedliving.net</name><uri>http://www.blogger.com/profile/15985241952228774254</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='19' height='32' src='http://bp1.blogger.com/_UCJi7Tzohac/SG58dAPxGkI/AAAAAAAAAAU/34fwqCcQtGQ/S220/John_CS.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-6743586198611027924.post-149362930753424914</id><published>2008-08-16T09:39:00.000-07:00</published><updated>2008-08-16T09:45:27.455-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='radiant floor heat'/><category scheme='http://www.blogger.com/atom/ns#' term='in floor radiant heating'/><category scheme='http://www.blogger.com/atom/ns#' term='hydronics in-floor radiant heating'/><title type='text'>Radiant floor heat Q&amp;A - Part I</title><content type='html'>&lt;strong&gt;The following questions were posted on &lt;span class="blsp-spelling-error" id="SPELLING_ERROR_0"&gt;GreenBuildingTalk&lt;/span&gt;.com....&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;hi,i am installing a geothermal and will have x gallons of hot water. i have read and looked at a lot of different designs for moving this water around and have some questions&lt;br /&gt;&lt;br /&gt;1) pump per zone or series pumps to do all? i have seen both?&lt;br /&gt;&lt;br /&gt;2) joist insulating. it seems the plates are &lt;span class="blsp-spelling-error" id="SPELLING_ERROR_1"&gt;everyones&lt;/span&gt; &lt;span class="blsp-spelling-error" id="SPELLING_ERROR_2"&gt;recomoindation&lt;/span&gt; but the after that insulating seems to have multiple options. foil / bat insulation / distance from &lt;span class="blsp-spelling-error" id="SPELLING_ERROR_3"&gt;pex&lt;/span&gt;??? has anyone yet determined the best?&lt;br /&gt;&lt;br /&gt;3) long loops and short loops on the same header. is this where the one common pump fails to work?&lt;br /&gt;&lt;br /&gt;4) i never seem to find any information on pump efficiencies?&lt;br /&gt;&lt;br /&gt;5) ready made systems? are there vendors that sell complete manifold / pump / &lt;span class="blsp-spelling-error" id="SPELLING_ERROR_4"&gt;thermo&lt;/span&gt; systems? seems there are but how about a reference for one&lt;br /&gt;&lt;br /&gt;thanks&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;Here's our response.....&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;&lt;/strong&gt;&lt;br /&gt;1) In a typical small to mid-size home, it's more efficient to use one single system pump -- and use 24v zone valves for zoning -- than to use a pump for each zone. Each pump can cost $30 to $50 per year to operate, depending on your local electric rates. Zone valves are a fraction of that to operate.&lt;br /&gt;&lt;br /&gt;2) Foil-faced bats with a minimum R-13 is a good way to go (install foil face up). Radiant heat wants to do just that -- radiate -- in all directions (most people assume "heat rises" -- no, warm air rises). Furthermore, radiant heat will radiate most towards the path of least resistance. In under-floor applications, the path of least resistance is typically down -- unless you insulate properly. Avoid "&lt;span class="blsp-spelling-error" id="SPELLING_ERROR_5"&gt;Astro&lt;/span&gt;-Foil." It's only rated for something like an R-4, and based on hard-learned lessons, it's terrible to use under radiant floors -- unless it's used in conjunction with fiberglass or blown-cellulose. I've seen people use &lt;span class="blsp-spelling-error" id="SPELLING_ERROR_6"&gt;Astro&lt;/span&gt;-foil just below the tubing to create the 1" air-space recommended by most radiant manufacturers, and then go over the &lt;span class="blsp-spelling-error" id="SPELLING_ERROR_7"&gt;Astro&lt;/span&gt;-foil with bats. This works well.&lt;br /&gt;&lt;br /&gt;3) As for loop-length. It will make life easier if you can make all loops fairly equal in length (within 10%) -- it will keep flow-rates through each loop fairly equal. That said, it's not always possible. Not a big deal. Most all brass, bronze or stainless-steel manifolds have balancing valves that allow you to balance flow-rates across the header. Also, if you &lt;span class="blsp-spelling-error" id="SPELLING_ERROR_8"&gt;really&lt;/span&gt; want to get slick, you can purchase manifolds with flow-meters to give you a visual indicator of flow through each loop -- and then use the balancing mechanism to equalize the loops. That said, NEVER install loops (or circuits, as they are most often referred to as) that exceed the recommended maximum circuit-length. For most brands of &lt;span class="blsp-spelling-error" id="SPELLING_ERROR_9"&gt;PEX&lt;/span&gt;, the maximum circuit-lengths for each size tubing is as followed:&lt;br /&gt;&lt;br /&gt;5/16 = 250'&lt;br /&gt;3/8 = 300'&lt;br /&gt;1/2 = 400'&lt;br /&gt;5/8 = 500'&lt;br /&gt;&lt;br /&gt;4) Pump-efficiency is a complicated engineering matter. If you're doing a residential install, you're likely going to use one of four makes of pump -- &lt;span class="blsp-spelling-error" id="SPELLING_ERROR_10"&gt;Grundfos&lt;/span&gt;, Taco, &lt;span class="blsp-spelling-error" id="SPELLING_ERROR_11"&gt;Wilo&lt;/span&gt; or Bell &amp;amp; &lt;span class="blsp-spelling-error" id="SPELLING_ERROR_12"&gt;Gosset&lt;/span&gt;. There are slight differences in each pump's efficiency, but only slight. You want to be concerned less with efficiency, and more concerned with choosing the right size pump -- not too small, not too big. In a typical 2-story 2,000 to 3,000 sq. ft. home, I almost always can use a &lt;span class="blsp-spelling-error" id="SPELLING_ERROR_13"&gt;Grundfos&lt;/span&gt; 1558 or Taco 007 (small pumps). There is a method for sizing pumps correctly, but would take too long to explain here. That said, you'll know you have the right size pump of the Delta-T (temperature difference) between the supply and return is about 20 degrees. If it's much more than that, your pump is too small. If it's less than 20 degrees, you're too big. If by chance your pump is too big, you can always install a balancing valve (a simple gate valve will do), and close it slightly (to restrict flow), until you get the desired Delta-T.&lt;br /&gt;&lt;br /&gt;5) There are "ready-made" systems, but I find that each has its limitations. There are some independent outfits making &lt;span class="blsp-spelling-error" id="SPELLING_ERROR_14"&gt;pre&lt;/span&gt;-&lt;span class="blsp-spelling-error" id="SPELLING_ERROR_15"&gt;fabbed&lt;/span&gt; control panels, but these are often rudimentary in design and, to be frank, "cheesy." The established radiant manufacturers often have &lt;span class="blsp-spelling-error" id="SPELLING_ERROR_16"&gt;pre&lt;/span&gt;-&lt;span class="blsp-spelling-error" id="SPELLING_ERROR_17"&gt;fabbed&lt;/span&gt; systems, but they are intended for &lt;span class="blsp-spelling-error" id="SPELLING_ERROR_18"&gt;pro's&lt;/span&gt; that know exactly what they need and understand how to integrate them into a larger design. What you might opt for is a custom-designed, &lt;span class="blsp-spelling-error" id="SPELLING_ERROR_19"&gt;pre&lt;/span&gt;-&lt;span class="blsp-spelling-error" id="SPELLING_ERROR_20"&gt;fabbed&lt;/span&gt; panel that is tailored exactly to your application, and come completely &lt;span class="blsp-spelling-error" id="SPELLING_ERROR_21"&gt;pre&lt;/span&gt;-wired, mixing and/or injection controls &lt;span class="blsp-spelling-error" id="SPELLING_ERROR_22"&gt;pre&lt;/span&gt;-programmed, etc. If you're interested in something like this, drop an e-mail to info@enhancedliving.net (put custom panel in the subject heading).&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/6743586198611027924-149362930753424914?l=enhancedlivingblog.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://enhancedlivingblog.blogspot.com/feeds/149362930753424914/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=6743586198611027924&amp;postID=149362930753424914' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/6743586198611027924/posts/default/149362930753424914'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/6743586198611027924/posts/default/149362930753424914'/><link rel='alternate' type='text/html' href='http://enhancedlivingblog.blogspot.com/2008/08/radiant-floor-heat-q-part-i.html' title='Radiant floor heat Q&amp;A - Part I'/><author><name>www.enhancedliving.net</name><uri>http://www.blogger.com/profile/15985241952228774254</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='19' height='32' src='http://bp1.blogger.com/_UCJi7Tzohac/SG58dAPxGkI/AAAAAAAAAAU/34fwqCcQtGQ/S220/John_CS.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-6743586198611027924.post-5741549703816429120</id><published>2008-08-10T10:10:00.000-07:00</published><updated>2008-08-11T03:50:45.270-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='switching heating fuels'/><category scheme='http://www.blogger.com/atom/ns#' term='fuel conversion'/><category scheme='http://www.blogger.com/atom/ns#' term='switching to natural gas'/><title type='text'>Converting to natural gas</title><content type='html'>If you live in a neighborhood served by natural gas, yet still use fuel oil to heat your home, what are you waiting for?!&lt;br /&gt;&lt;br /&gt;Traditionally, natural gas and fuel oil, have been very cost-competitive in the Northeast. Today, however, it costs nearly double to heat with fuel oil than with natural gas. On top of that, heating systems fueled by natural gas require far less maintenance and are less prone to failure than oil-fired equipment.&lt;br /&gt;&lt;br /&gt;Converting your system is generally a simple affair. The process starts with a call to your gas provider. So as long as your home is relatively close to the main (within 100') most gas utilities will connect your home at no charge.&lt;br /&gt;&lt;br /&gt;While the utility company will make the connection between the main and the meter (which they provide), it is the homeowner's responsibility to connect the home appliances to the meter. In many cases, this is a simple affair and can normally be performed by your heating contractor or plumber for less than $1,500.&lt;br /&gt;&lt;br /&gt;Now to your heating system. More often than not, converting your oil-fired boiler or furnace is simple as swapping the oil burner for a new gas one. That said, this is a good time to consider a full system replacement.&lt;br /&gt;&lt;br /&gt;Today's gas-fired heating systems can exceed 95 percent efficiency, and the price of natiral gas, while a bargain compared to oil, is predicted to rise, as well (though not to the level of fuel oil).&lt;br /&gt;&lt;br /&gt;If you live in New York's Capital Region, and would like to convert your home to natural gas, contact &lt;a href="http://www.enhancedliving.net/"&gt;Enhanced Living&lt;/a&gt; for free consultation.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/6743586198611027924-5741549703816429120?l=enhancedlivingblog.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://enhancedlivingblog.blogspot.com/feeds/5741549703816429120/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=6743586198611027924&amp;postID=5741549703816429120' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/6743586198611027924/posts/default/5741549703816429120'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/6743586198611027924/posts/default/5741549703816429120'/><link rel='alternate' type='text/html' href='http://enhancedlivingblog.blogspot.com/2008/08/converting-to-natural-gas.html' title='Converting to natural gas'/><author><name>www.enhancedliving.net</name><uri>http://www.blogger.com/profile/15985241952228774254</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='19' height='32' src='http://bp1.blogger.com/_UCJi7Tzohac/SG58dAPxGkI/AAAAAAAAAAU/34fwqCcQtGQ/S220/John_CS.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-6743586198611027924.post-6190505473730412851</id><published>2008-07-27T09:04:00.000-07:00</published><updated>2008-07-27T16:27:28.591-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='sizing water heaters'/><category scheme='http://www.blogger.com/atom/ns#' term='commercial water heating sizing'/><title type='text'>Water heater sizing guide</title><content type='html'>As homes get larger, and bathrooms more customized with larger and larger showers and tubs, the standard 40-gallon water heater isn't the one-size-fits-all appliance it once was.&lt;br /&gt;&lt;br /&gt;Furthermore, as energy prices continue to rise along with the size of a home's hot water demand, the options in water heating technology have grown wide and varied. To help you select the correct water heater that both ensures you never run out, while at the same time, don't produce far more than you need, here are a few tips and techniques for selecting the right size appliance.&lt;br /&gt;&lt;br /&gt;Since the goal is to never run out of hot water, always assume a worst-case scenario. This means delivering enough hot water based on the assumption that every tap and hot water-consuming appliance (i.e. laundry machines, dishwasher) will be used simultaneously.&lt;br /&gt;&lt;br /&gt;With that in mind, calculate the gallons-per-minute (gpm) demand at every draw-point and fixture. To figure out the gpm-demand of any given fixture, get a one-gallon container (like a milk jug) and a watch with a minute-hand. See how long it takes to fill and the container and do the math (if the jug fills in 30-seconds, the flow-rate would be 2 gpm). For appliances like dishwashers and clothes washers, the water-consumption data will often be provided in the manufacturer's literature.&lt;br /&gt;&lt;br /&gt;Once you've added the total gpm for all appliances, multiply by .85. Why? Your water heater will usually maintain a temperature of 120-degrees, however, you usually temper this down with a bit of cold water to about 100 degrees -- 100 degrees is about 85% of 120. Once you multiply the demand of all fixtures and appliances by .85, this is the total gpm that you need from your water heater.&lt;br /&gt;&lt;br /&gt;For on-demand water heaters, figuring-out the size you need is pretty cut and dry. All manufacturers provide output-data (expressed in gpm) based on a specific temperature rise. The rise refers to the difference in temperature between what you'll heat the water to minus the temperature of the water as it enters the home. In many parts of the U.S., water enters the home at about 55 degrees and is heated to 120 degrees -- a rise of 75.&lt;br /&gt;&lt;br /&gt;If the output of the on-demand water heater exceeds the demand of your home, you have a winner. In some cases, however, your demand will be larger than the output of the on-demand water heater (this is fairly common in larger homes). If this is the case, you can either use multiple on-demand water heaters or move to a large tank-type model. In most cases, it's more cost-effective to purchase a large-capacity tank versus multiple on-demand systems.&lt;br /&gt;&lt;br /&gt;If you opt for a tank-type water heater, you'll want to refer to the appliance's "First-Hour Rating." This number basically equates to the number of gallons a water heater can provide per hour. Take this number, divide it by 60, and this the the total gpm the water heater can deliver. If the first-hour rating (divided by 60) is larger than the total gpm demand calculated for your home, the water heater should do the trick&lt;strong&gt;. &lt;/strong&gt;&lt;strong&gt;But there's an exception. &lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;The First-Hour Rating doesn't account for a potential "dump load." Here's what we mean. If you have a 40-gallon water heater, but have a bath tub that holds 50 gallons, there's a strong likelihod that the water heater will become depleted, unless it has a super-huge burner like those found in commercial water heaters (big bucks). So, if you have a large soaking tub, we recommend you purchase a water heater that has a capacity that's &lt;em&gt;at least&lt;/em&gt; 1.5 times the size of the tub.&lt;br /&gt;&lt;br /&gt;Why more? Two reasons.&lt;br /&gt;&lt;br /&gt;First, just because the tank says 60 gallons, you don't actually get 60 gallons of hot water. As you fill the tub, emptying hot water from the tank, it gets replaced by cold water. Consequently, this cold water mixes-down the the temperature of the tanks hot water, thus diminishing the amount of total available hot water.&lt;br /&gt;&lt;br /&gt;Second, again, we want to assume that other fixtures will be in use as you fill the big tub. By oversizing by a factor of 50 percent, we allow for extra demand.&lt;br /&gt;&lt;br /&gt;Sizing water heaters is as much art as it is science. When in doubt, contact a &lt;a href="http://www.enhancedliving.net/"&gt;qualified professional&lt;/a&gt;. Furthermore, by allowing an installation contractor to size the appliance for you, you're putting the liability on him (or her) instead of assuming the risk yourself.&lt;br /&gt;&lt;strong&gt;&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;Commercial Applications:&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;Commercial water heating applications can be much more varied, and sometimes requires a more sophisticated approach to calculating the correct size appliance(s). Moreover, commercial equipment can be very expensive. At the same time, water heating can represent a lrge percentage of a business' energy overhead. As a result, it is important to get it right -- the first time.&lt;br /&gt;&lt;br /&gt;Many factors come into play in commercial water heating applications -- overall demand, time of use, energy costs, storage needs versus btu-output, etc. If you have a commercial water heating need, we highly recommend you either: 1) hire &lt;a href="http://www.enhancedliving.net/"&gt;Enhanced Living&lt;/a&gt; to design your system, or 2) hire a mechanical engineer with specific expertise in this area.&lt;br /&gt;&lt;br /&gt;If you have fairly generic needs and/or a small demand, use the above guidelines for residential applications, or use one of the following calculators:&lt;br /&gt;&lt;ul&gt;&lt;li&gt;&lt;a href="http://www.hotwater.com/accusize.html"&gt;A.O. Smith's Accu-Size-Program&lt;/a&gt;&lt;/li&gt;&lt;li&gt;&lt;a href="http://www.bradfordwhite.com/rightspec.asp"&gt;Bradford White's RightSpec Program&lt;/a&gt; &lt;/li&gt;&lt;/ul&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/6743586198611027924-6190505473730412851?l=enhancedlivingblog.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://enhancedlivingblog.blogspot.com/feeds/6190505473730412851/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=6743586198611027924&amp;postID=6190505473730412851' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/6743586198611027924/posts/default/6190505473730412851'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/6743586198611027924/posts/default/6190505473730412851'/><link rel='alternate' type='text/html' href='http://enhancedlivingblog.blogspot.com/2008/07/water-heater-sizing-guide.html' title='Water heater sizing guide'/><author><name>www.enhancedliving.net</name><uri>http://www.blogger.com/profile/15985241952228774254</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='19' height='32' src='http://bp1.blogger.com/_UCJi7Tzohac/SG58dAPxGkI/AAAAAAAAAAU/34fwqCcQtGQ/S220/John_CS.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-6743586198611027924.post-5764412147325353339</id><published>2008-07-27T08:10:00.000-07:00</published><updated>2008-12-08T15:59:33.810-08:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='indirect-fired water heaters'/><category scheme='http://www.blogger.com/atom/ns#' term='Boilermate'/><title type='text'>Product Alert:  Amtrol Boiler Mate</title><content type='html'>In the quest for a low-cost indirect water heater, many contractors and homeowners turn to &lt;span class="blsp-spelling-error" id="SPELLING_ERROR_0"&gt;Amtrol's&lt;/span&gt; &lt;span class="blsp-spelling-error" id="SPELLING_ERROR_1"&gt;BoilerMate&lt;/span&gt;. Big mistake. Not only is the &lt;span class="blsp-spelling-error" id="SPELLING_ERROR_2"&gt;BoilerMate&lt;/span&gt; poorly insulated -- a mere 3/4" layer of insulation -- it utilizes a finned-coil heat-exchanger.&lt;br /&gt;&lt;div&gt;&lt;div&gt;&lt;br /&gt;&lt;/div&gt;&lt;div&gt;With one notable exception*, most indirect-fired water heaters utilize one of two styles of internal heat-exchanger -- either a copper finned-tube, or a smooth steel coil. &lt;/div&gt;&lt;div&gt;&lt;br /&gt;&lt;/div&gt;&lt;div&gt;Avoid finned-tube heat-exchangers, especially if you have relatively hard water. The problem is that minerals within the water cling easily to finned-tubes, to the point that they become coated entirely in mineral-scale. When this happens, the mineral-scale inhibits the heat-exchanger's ability to transfer heat to the stored water, causing the attached boiler to short-cycle and operate extremely inefficiently. &lt;/div&gt;&lt;div&gt;&lt;br /&gt;&lt;/div&gt;&lt;div&gt;Think this is just theory? Think again. Below is a photograph of an eight year-old &lt;span class="blsp-spelling-error" id="SPELLING_ERROR_3"&gt;BoilerMate&lt;/span&gt; with its finned-tube heat-exchanger removed. The white layers of mineral scale are clearly apparent.&lt;br /&gt;&lt;br /&gt;&lt;/div&gt;&lt;img id="BLOGGER_PHOTO_ID_5227720216252910306" style="DISPLAY: block; MARGIN: 0px auto 10px; CURSOR: hand; TEXT-ALIGN: center" alt="" src="http://3.bp.blogspot.com/_UCJi7Tzohac/SIyX1sriCuI/AAAAAAAAABg/BrzCwTUpKGs/s320/boilermate_w_HX.jpg" border="0" /&gt;&lt;br /&gt;&lt;p&gt;&lt;/p&gt;&lt;div&gt;We discovered this gem at a client's home. While he new something was awry with his heating system, evidenced by a slow, gradual climb in heating costs, he didn't think much of the fact that his boiler would operate nearly constantly -- turning on and off, on and off, throughout the day, as the water heater struggled to make hot water. &lt;/div&gt;&lt;div&gt; &lt;/div&gt;&lt;/div&gt;&lt;div&gt;&lt;/div&gt;&lt;div&gt;Once replaced by a &lt;a href="http://www.viessmann-us.com/en/products/speicher-wassererwaermer/Vitocell-V_100.html"&gt;&lt;span class="blsp-spelling-error" id="SPELLING_ERROR_4"&gt;Viessmann&lt;/span&gt; &lt;span class="blsp-spelling-error" id="SPELLING_ERROR_5"&gt;Vitocell&lt;/span&gt; 100&lt;/a&gt; (the original H.B. Smith boiler was also replaced with a &lt;a href="http://www.viessmann-us.com/en/products/Oil-fired_boilers_/Vitorond_100_18kW.html"&gt;&lt;span class="blsp-spelling-error" id="SPELLING_ERROR_6"&gt;Viessmann&lt;/span&gt; &lt;span class="blsp-spelling-error" id="SPELLING_ERROR_7"&gt;Vitorond&lt;/span&gt; 100&lt;/a&gt;), the improvement was immediately noticed. The new boiler/tank combo runs like a top, with a huge increase in efficiency and an abundance of hot water. &lt;/div&gt;&lt;div&gt;&lt;/div&gt;&lt;div&gt; &lt;/div&gt;&lt;div&gt;Moral of the story -- avoid finned-tube heat-exchangers. Even if you're on a tight budget, there are &lt;span class="blsp-spelling-error" id="SPELLING_ERROR_8"&gt;plen&lt;/span&gt;&lt;span class="blsp-spelling-error" id="SPELLING_ERROR_9"&gt;ty&lt;/span&gt; of low-cost indirect-fired water heaters that utilize a smooth-walled steel coil. &lt;/div&gt;&lt;div&gt; &lt;/div&gt;&lt;div&gt;&lt;/div&gt;&lt;div&gt;&lt;span style="font-size:85%;"&gt;&lt;strong&gt;* The notable exception is &lt;/strong&gt;&lt;/span&gt;&lt;a href="http://www.triangletube.com/Residential/ProductIWH.htm"&gt;&lt;span style="font-size:85%;"&gt;&lt;strong&gt;Triangle Tube's Phase III&lt;/strong&gt;&lt;/span&gt;&lt;/a&gt;&lt;span style="font-size:85%;"&gt;&lt;strong&gt; water heater, which utilizes a "tank-in-tank" design. The Phase III is a quality indirect-fired water heater -- a good choice among stainless steel tanks.&lt;/strong&gt;&lt;/span&gt; &lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/6743586198611027924-5764412147325353339?l=enhancedlivingblog.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://enhancedlivingblog.blogspot.com/feeds/5764412147325353339/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=6743586198611027924&amp;postID=5764412147325353339' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/6743586198611027924/posts/default/5764412147325353339'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/6743586198611027924/posts/default/5764412147325353339'/><link rel='alternate' type='text/html' href='http://enhancedlivingblog.blogspot.com/2008/07/product-alert-amtrol-boiler-mate.html' title='Product Alert:  Amtrol Boiler Mate'/><author><name>www.enhancedliving.net</name><uri>http://www.blogger.com/profile/15985241952228774254</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='19' height='32' src='http://bp1.blogger.com/_UCJi7Tzohac/SG58dAPxGkI/AAAAAAAAAAU/34fwqCcQtGQ/S220/John_CS.jpg'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://3.bp.blogspot.com/_UCJi7Tzohac/SIyX1sriCuI/AAAAAAAAABg/BrzCwTUpKGs/s72-c/boilermate_w_HX.jpg' height='72' width='72'/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-6743586198611027924.post-4904797488239853587</id><published>2008-07-27T07:46:00.001-07:00</published><updated>2008-07-27T08:54:12.000-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='blower door test'/><category scheme='http://www.blogger.com/atom/ns#' term='energy audits'/><title type='text'>Energy Audits Get Hot..EL on Businessweek.com</title><content type='html'>Enhanced Living makes national press -- &lt;a href="http://www.businessweek.com/investor/content/dec2005/pi2005121_4811_pi001.htm?campaign_id=search"&gt;Read about Energy Audits on Businessweek.com&lt;/a&gt;.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/6743586198611027924-4904797488239853587?l=enhancedlivingblog.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://enhancedlivingblog.blogspot.com/feeds/4904797488239853587/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=6743586198611027924&amp;postID=4904797488239853587' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/6743586198611027924/posts/default/4904797488239853587'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/6743586198611027924/posts/default/4904797488239853587'/><link rel='alternate' type='text/html' href='http://enhancedlivingblog.blogspot.com/2008/07/energy-audits-get-hotel-on.html' title='Energy Audits Get Hot..EL on Businessweek.com'/><author><name>www.enhancedliving.net</name><uri>http://www.blogger.com/profile/15985241952228774254</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='19' height='32' src='http://bp1.blogger.com/_UCJi7Tzohac/SG58dAPxGkI/AAAAAAAAAAU/34fwqCcQtGQ/S220/John_CS.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-6743586198611027924.post-8849973261302310314</id><published>2008-07-27T07:36:00.000-07:00</published><updated>2008-07-27T08:54:30.666-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='central humidifiers'/><title type='text'>Avoid whole-house humidifiers</title><content type='html'>Cold weather brings dry homes. And dry homes bring itchy skin, scratchy throats, and irritated sinuses.&lt;br /&gt;&lt;br /&gt;To counter the effects of "dry house syndrome," the first thing homeowners and contractors often reach for is a central humidifier.&lt;br /&gt;&lt;p&gt;If you happen to be an admitted germ-phobe, central humidifiers aren't for you. Think swamp-environment. That's the best way to describe the conditions inside your furnace-attached humidifier; a breeding-ground for bacteria, viruses, and molds.&lt;/p&gt;If you have leaky ducts that run through an unconditioned area, such as the attic, warm "humidified" air is able to escape and condense on the cold roof-deck, causing costly moisture-damage and/or rot.&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;p&gt;If you want to maintain comfortable winter humidity levels (+-40 percent RH), here's a more "holistic" approach:&lt;/p&gt;&lt;ol&gt;&lt;li&gt;&lt;span class="bold2"&gt;Reduce your homes air-leaks&lt;/span&gt;. Cutting the homes air-infiltration rate reduces the amount of moisture that gets lost to the outside. Reducing air-leaks also reduces drafts and saves energy.&lt;br /&gt;&lt;br /&gt;CAVEAT: In our opinion, there's no such thing as an "overtight" home -- only an underventilated one. That said, if you don't have adequate ventilation, excess moisture can be a problem in tight homes. Additionally, overtightening the home in a manner that seals-off a furnace' or water-heaters source of combustion air increase the risk of back-drafting the chimney and introducing carbon monoxide into the home.&lt;/li&gt;&lt;br /&gt;&lt;li&gt;&lt;span class="bold2"&gt;Consider an energy-recovery ventilator (ERV)&lt;/span&gt;. ERVs like their close-cousin, the heat-recovery ventilator (HRV), are 'balanced' ventilation systems. Conventional exhaust-only ventilators (i.e. standard bathroom fan) get their make-up air by pulling it through the cracks and leaks in the home. Not a very well-controlled method, and certainly not the best for indoor air quality.&lt;/li&gt;&lt;/ol&gt;&lt;p&gt;Balanced ventilators, like ERVs and HRVs, bring fresh air into the home by way of dedicated ducts. As an added bonus, HRVs 'recover' a portion of the heat that normally gets exhausted and returns it back inside the home, a nice energy-efficiency feature. ERVs have an added-added bonus. They recover heat AND humidity and help keep clean, fresh-air circulating through the home without drying-it out in winter. Controls prevent the unit from causing excessive humidity-levels that can lead to condensation build-up on windows, or more serious&lt;br /&gt;moisture problems.&lt;/p&gt;&lt;p&gt;Balanced ventilators, like ERVs and HRVs, also help minimize the risk of chimney back-drafting. Some models have built-in HEPA filters for even better indoor air quality.&lt;/p&gt;&lt;p&gt;You'll have to spend more money in the short-term, but the benefits of this two-pronged approach are multi-fold -- cleaner air, a safer home, lower energy bills, and greater comfort. And believe us, the goopy, sticky stuff that's sticking to the bottom of your humdifier is nasty.&lt;/p&gt;&lt;p&gt;For the intrepid DIY'er, a good selection of home ventilation systems are available at&lt;br /&gt;&lt;a href="http://www.blogger.com/post-create.g?blogID=6743586198611027924#" target="_blank"&gt;&lt;/a&gt;MoreHome.com, including HRV/ERVs. They compare competitively price-wise, and are&lt;br /&gt;certainly less expensive than what a contractor charges to install (not that it isn't worth, but hey, if you know what you're doing, why not save a few bucks).&lt;/p&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/6743586198611027924-8849973261302310314?l=enhancedlivingblog.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://enhancedlivingblog.blogspot.com/feeds/8849973261302310314/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=6743586198611027924&amp;postID=8849973261302310314' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/6743586198611027924/posts/default/8849973261302310314'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/6743586198611027924/posts/default/8849973261302310314'/><link rel='alternate' type='text/html' href='http://enhancedlivingblog.blogspot.com/2008/07/avoid-whole-house-humidifiers.html' title='Avoid whole-house humidifiers'/><author><name>www.enhancedliving.net</name><uri>http://www.blogger.com/profile/15985241952228774254</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='19' height='32' src='http://bp1.blogger.com/_UCJi7Tzohac/SG58dAPxGkI/AAAAAAAAAAU/34fwqCcQtGQ/S220/John_CS.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-6743586198611027924.post-4887898671279812002</id><published>2008-07-27T06:45:00.000-07:00</published><updated>2008-12-08T15:59:34.009-08:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='attic mold'/><category scheme='http://www.blogger.com/atom/ns#' term='attic ventilation'/><title type='text'>Misunderstanding attic ventilation</title><content type='html'>One of the most misunderstood areas of home construction and maintenance is the long-held rule that attic ventilation helps extend the life of a roof. The general assumption is that ventilation -- whether a ridge-vent, gable vents, or what have you -- allows the attic-space to "air-out," therefore keeping the underside of the roof-decking dry. Sounds reasonable enough. But it's simply unfounded. In the photo (below), this attic was equipped with a ridge-vent, and (visible) soffit vents -- yet still received costly moisture and mold damage. &lt;div&gt;&lt;/div&gt;&lt;img id="BLOGGER_PHOTO_ID_5227700652719940514" style="DISPLAY: block; MARGIN: 0px auto 10px; CURSOR: hand; TEXT-ALIGN: center" alt="" src="http://1.bp.blogspot.com/_UCJi7Tzohac/SIyGC81zI6I/AAAAAAAAABA/49e42vYykNI/s320/saratoga+mold+003.jpg" border="0" /&gt;&lt;br /&gt;&lt;div&gt;Though most building codes require a minimum of 1 sq. ft. of ventilation per every 300 sq. ft., the 300:1 rule, as it is commonly known, has no basis in building science. In fact, a paper titled, "&lt;a href="https://www.nrca.net/rp/technical/files/7877.pdf"&gt;The History of Attic Ventilation, Regulation and Research&lt;/a&gt;" found no concrete scientific basis for the 300:1 rule, which was first put in motion in 1942 by writers of the Federal Housing Agency. The rule, according to Rose, was arbitrarily enacted with no research or field-evidence to support it.&lt;br /&gt;&lt;/div&gt;&lt;br /&gt;&lt;div&gt;Since the 1940's, home construction methods have changed dramatically. Then, roof-decking consisted of board (plank) sheathing, a rather "breathable" material. Today, we employ continuous sheets of plywood or oriented strand board (OSB), which creates a relatively air-tight barrier to the outside. Additionally, homes built in the early to mid-20th century contained little, if any, attic insulation, whereas today, we build tight, well-insulated homes. &lt;/div&gt;&lt;br /&gt;&lt;div&gt;&lt;/div&gt;&lt;div&gt;This change in building materials and construction techniques creates an entirely different dynamic in terms of the way a home behaves under certain temperature and/or moisture conditions.&lt;/div&gt;&lt;br /&gt;&lt;div&gt;When an attic is uninsulated, the space becomes semi-conditioned, as it receives heat that rises and escapes from the conditioned areas below. This rising heat also brings with it moisture, in the form of vapor, the main culprit in roof failures. In a semi-conditioned environment, this moisture tends to stay in vapor state, since the dew-point is never reached, which means condensation can't occur. &lt;/div&gt;&lt;br /&gt;&lt;div&gt;In a well-insulated attic, the space becomes completely unconditioned. Little heat reaches the attic, making the attic a much colder space. And since few builders to a good job of air-sealing the attic plane (the ceiling of the rooms below), moisture-vapor still reaches the attic space. Except in this scenario, the temperature of the attic DOES reach dew-point, causing the vapor to condense into liquid water, which ultimately kills the roof.&lt;/div&gt;&lt;br /&gt;&lt;div&gt;The point to all of this?&lt;/div&gt;&lt;br /&gt;&lt;div&gt;&lt;/div&gt;&lt;div&gt;Homeowners in cold climates sometimes experience damaged, decayed roof systems caused by condensing moisture. And when they run into this problem, the first people the often call is a roofer or general contractor. And with almost 100-percent certainty, the first recommendation they make is -- add attic ventilation.&lt;/div&gt;&lt;br /&gt;&lt;div&gt;&lt;/div&gt;&lt;div&gt;Why is this bad?&lt;/div&gt;&lt;br /&gt;&lt;div&gt;&lt;/div&gt;&lt;div&gt;Attic ventilation inherently increases the "stack-effect of a home, increasing air and moisture-movement into the attic. More moisture means more problems. Furthermore, there's no scientific evidence that attic ventilation does what it's purported to do, which is allow the roof to air-out and dry sufficiently to head-off moisture-damage. It's merely an assumption that we've all gone along with, without question.&lt;/div&gt;&lt;br /&gt;&lt;div&gt;&lt;/div&gt;&lt;div&gt;If the roofer or GC is worth their salt, they'll recommend not more attic ventilation, but a combination of air-sealing and MECHANICAL ventilation. Sealing the attic plane keeps moisture out of the attic altogether. Mechanical ventilation, such as a properly sized bathroom, removes excess water-vapor from the entire home. &lt;/div&gt;&lt;br /&gt;&lt;div&gt;&lt;/div&gt;&lt;div&gt;Cathedral ceilings, where there's no attic at all, receives similar treatment. The ceiling itself should be very well-sealed to prevent moist air from getting inside. If recessed lights are installed in the ceiling, use only sealed canisters. If using a finish other than sheetrock or plywood, such as tongue and groove panels, a continuous moisture-barrier should be installed between the finished ceiling and the rafters.&lt;/div&gt;&lt;br /&gt;&lt;div&gt;&lt;/div&gt;&lt;div&gt;According to building science expert Joseph Lstiburek, one extra level of defense to protect cathedral ceilings (in cold climates only) is to install a layer of rigid-foam insulation on the outside of the roof-decking. This keeps the underside of the decking warm and inhibits condensation.&lt;/div&gt;&lt;br /&gt;&lt;div&gt;&lt;/div&gt;&lt;div&gt;The nice thing about the one-two punch of air-sealing and mechanical ventilation, is that it's also better for energy bills, while reducing uncomfortable drafts.&lt;/div&gt;&lt;br /&gt;&lt;div&gt;&lt;/div&gt;&lt;div&gt;So if you have the great misfortune of a failed roof, don't call the roofer until you've first hired an insulator to seal the home, and an HVAC technician to check and/or upgrade the adequacy of your mechanical ventilation.&lt;/div&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/6743586198611027924-4887898671279812002?l=enhancedlivingblog.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://enhancedlivingblog.blogspot.com/feeds/4887898671279812002/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=6743586198611027924&amp;postID=4887898671279812002' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/6743586198611027924/posts/default/4887898671279812002'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/6743586198611027924/posts/default/4887898671279812002'/><link rel='alternate' type='text/html' href='http://enhancedlivingblog.blogspot.com/2008/07/misunderstanding-attic-ventilation.html' title='Misunderstanding attic ventilation'/><author><name>www.enhancedliving.net</name><uri>http://www.blogger.com/profile/15985241952228774254</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='19' height='32' src='http://bp1.blogger.com/_UCJi7Tzohac/SG58dAPxGkI/AAAAAAAAAAU/34fwqCcQtGQ/S220/John_CS.jpg'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://1.bp.blogspot.com/_UCJi7Tzohac/SIyGC81zI6I/AAAAAAAAABA/49e42vYykNI/s72-c/saratoga+mold+003.jpg' height='72' width='72'/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-6743586198611027924.post-5239550586505073398</id><published>2008-07-24T19:44:00.000-07:00</published><updated>2008-07-27T08:55:16.549-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='energy efficient heating'/><category scheme='http://www.blogger.com/atom/ns#' term='high oil prices'/><title type='text'>Beating high oil prices -- Serious efficiency upgrades you can do for under $1,000</title><content type='html'>Faced with a near-doubling of oil prices as we head toward another heating season, many homeowners are looking for ways to increase the &lt;span class="blsp-spelling-corrected" id="SPELLING_ERROR_0"&gt;efficiency&lt;/span&gt; of their oil-heating systems. Here are a few recommendations on beating the high cost of oil with upgrades and improvements that cost under $1,000.&lt;br /&gt;&lt;strong&gt;&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;1) Outdoor reset control (hot water systems)&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;Also called weather-responsive controls, these electronic devices operate on the simple premise that lower boiler-supply temperatures results in increased fuel savings.&lt;br /&gt;&lt;br /&gt;Most boiler systems are designed to heat the home on the coldest day of the year (in the Albany, NY area, we consider this to be about -7 degrees F) using a boiler supply-temperature of around 180 degrees F.&lt;br /&gt;&lt;br /&gt;Since 98 percent of the heating system is above -7 degrees -- 67 percent of the season is actually above 30 degrees F -- it's possible to adequately heat your home with substantially lower boiler-supply temperatures.&lt;br /&gt;&lt;br /&gt;Outdoor-reset controls modulate the temperature of the boiler based on the outdoor temperature; increasing water-temperatures as the outdoor temperature drops, and decreasing water-temperatures in milder weather.&lt;br /&gt;&lt;br /&gt;Most outdoor-reset controls typically improve boiler-efficiency by 15 percent.&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;2) Becket &lt;span class="blsp-spelling-error" id="SPELLING_ERROR_1"&gt;HeatManager (hot water systems)&lt;/span&gt;&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;Becket's &lt;span class="blsp-spelling-error" id="SPELLING_ERROR_2"&gt;HeatManager&lt;/span&gt; is an add-on boiler control that improves &lt;span class="blsp-spelling-corrected" id="SPELLING_ERROR_3"&gt;efficiency&lt;/span&gt; by better-managing on-off cycling of the oil burner. Costing around $575-$650 installed, the &lt;span class="blsp-spelling-error" id="SPELLING_ERROR_4"&gt;HeatManager&lt;/span&gt; comes with 10% fuel-savings guarantee from the manufacturer.&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;3) Professional clean &amp;amp; tune (hot water, forced air &amp;amp; steam systems)&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;Most people with oil systems are &lt;span class="blsp-spelling-corrected" id="SPELLING_ERROR_5"&gt;diligent&lt;/span&gt; in having their oil-fired boiler cleaned each season. The problem is that the technician called-in to do the job isn't so diligent in properly tuning the burner for maximum efficiency.&lt;br /&gt;&lt;br /&gt;Most technicians fail to use an electronic combustion-analyzer and other diagnostic devices to make precise adjustments to the burner. A thorough cleaning followed by a proper tune-up can improve efficiency by as much as 10 percent.&lt;br /&gt;&lt;br /&gt;Contractors and technicians who own the proper testing gear will typically charge $250 to $300 to clean &amp;amp; tune your oil-fired- heating system.&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;4) Minor ductwork improvements (forced air systems)&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;The vast majority of duct systems rob the energy-performance of the furnace by as much as 20 percent. Poor duct design and/or installation can cause restrictions in the path of air-flow and force the furnace to work harder than it should.&lt;br /&gt;&lt;br /&gt;A simple 5-minute static-pressure test by a knowledgeable technician can reveal energy-robbing air-flow problems, many of which can be remedied with minor changes to the ductwork.&lt;br /&gt;&lt;br /&gt;These relatively easy and cost-effective upgrades my include the installation of turning-vanes at critical transitions, or replacing flex-duct with hard pipe.&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;5) Burner de-rating (Hot Water &amp;amp; Warm Air Systems)&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;Most homeowners own heating systems that are oversized for their actual needs. The reason for oversizing usually results from the original contractor's failure to perform a proper heat-loss analyses of the home prior to installation. Homeowners faced with this situation can often have their burner "de-rated," or in other words, reduce its output in order to burn less oil.&lt;br /&gt;&lt;br /&gt;Burners should only be de-rated by a highly qualified technician. Done incorrectly, one can cause the burner to malfunction and result in frequent lock-outs. More serious, improper de-rating can result in dangerous excessive production of carbon monoxide.&lt;br /&gt;&lt;br /&gt;To properly de-rate your burner, a smart technician will first contact the equipment manufacturer, who in turn will provide information on the correct nozzle, as well as the new settings for the burner. Following the manufacturer's guidelines, the technician will fine-tune the burner using an electronic combustion-analyzer and other testing devices.&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;All of the above upgrades and improvements are available from &lt;/strong&gt;&lt;strong&gt;Enhanced Living, Inc. For consultation, call (518) 235-0311 or e-mail &lt;a href="mailto:info@enhancedliving.net"&gt;info@enhancedliving.net&lt;/a&gt;. &lt;/strong&gt;&lt;strong&gt;&lt;/strong&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/6743586198611027924-5239550586505073398?l=enhancedlivingblog.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://enhancedlivingblog.blogspot.com/feeds/5239550586505073398/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=6743586198611027924&amp;postID=5239550586505073398' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/6743586198611027924/posts/default/5239550586505073398'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/6743586198611027924/posts/default/5239550586505073398'/><link rel='alternate' type='text/html' href='http://enhancedlivingblog.blogspot.com/2008/07/beating-high-oil-prices-serious.html' title='Beating high oil prices -- Serious efficiency upgrades you can do for under $1,000'/><author><name>www.enhancedliving.net</name><uri>http://www.blogger.com/profile/15985241952228774254</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='19' height='32' src='http://bp1.blogger.com/_UCJi7Tzohac/SG58dAPxGkI/AAAAAAAAAAU/34fwqCcQtGQ/S220/John_CS.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-6743586198611027924.post-8755778233574603169</id><published>2008-07-17T18:36:00.000-07:00</published><updated>2008-07-27T08:56:00.756-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='Rinnai'/><category scheme='http://www.blogger.com/atom/ns#' term='Bosch'/><category scheme='http://www.blogger.com/atom/ns#' term='indirect-fired water heater'/><category scheme='http://www.blogger.com/atom/ns#' term='tankless water heaters'/><category scheme='http://www.blogger.com/atom/ns#' term='Takagi'/><title type='text'>Water-heaters:  On-demand tankless vs. Indirect-fired storage tanks</title><content type='html'>What's better -- tankless, on-demand water heaters or indirect-fired storage tanks? This question gets asked to us at least once a week. My answer: it depends.&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;Tankless water-heaters:&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;&lt;/strong&gt;&lt;br /&gt;Tankless, on-demand water heaters like those by Rinnai, Bosch, Takagi and many others, are a major improvement from the old-fashioned atmospheric domestic hot water tank. With a typical efficiency factor of .55, standard water heaters waste most of their energy while sitting unused, losing their heat through wimpy insulation, and an exhaust-pipe connected to the outside. Tankless, on-demand water heaters avoid these "standy-losses" by avoiding the whole process of storage altogether.&lt;br /&gt;&lt;br /&gt;From a combustion-efficiency standpoint, gas-fired on-demand water heaters get a so-so grade. Most models usually come with efficiency-ratings between 81 and 85 percent. Not terrible, but not record-breaking, either.&lt;br /&gt;&lt;br /&gt;(NOTE: If you're served by low-cost electricity, an electric on-demand water heater -- virtually 100 percent-efficient with no combustion whatsoever -- might be the way to go.)&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;Indirect-fired DHW:&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;&lt;/strong&gt;&lt;br /&gt;Indirect-fired water heaters are insulated storage vessels that are heated &lt;em&gt;indirectly&lt;/em&gt;, usually from a hot water boiler. Although they store hot water, they have no flue-pipe from which heat can escape.&lt;br /&gt;&lt;br /&gt;The efficiency of indirect-fired water heaters depends chiefly on two factors -- the effectiveness of the tank's insulation, and the efficiency of the boiler it's connected to.&lt;br /&gt;&lt;br /&gt;With a few cheap exceptions, most indirect-fired water heaters have two inch-thick polyurethane foam insulation. With two inches of insulation, most indirect-fired tanks have a standby-loss of around a half-degree per hour -- in most cases, a negligible loss.&lt;br /&gt;&lt;br /&gt;Modern boiler efficiencies usually range in between 84 and 95 percent. If the indirect-fired storage tank is located near the boiler and the supply/return piping is insulated to minimize energy-losses, the efficiency of the water heater will be close to that of the boiler.&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;Side-by-Side Comparison:&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;From an energy-efficiency standpoint, on-demand water heaters and indirect-fired storage tanks are, for all intents and purposes, fairly equal.&lt;br /&gt;&lt;br /&gt;From an installation-cost standpoint, in most cases, the two options are close in price, depending on the size and quality of the equipment you select and the difficulty of the installation.&lt;br /&gt;&lt;br /&gt;The final factor in deciding the better of the two options is life-expectancy.&lt;br /&gt;&lt;br /&gt;Most on-demand water heater manufacturers offer a ten to twelve-year limited warranty. The practical life-expectancy of on-demand units is somewhere around 15 years, depending on water conditions and other factors.&lt;br /&gt;&lt;br /&gt;The life expectancy of indirect-fired water heaters, on the other hand, can range widely depending on the material they're made from. Lower-end coated steel tanks can last anywhere from eight to twenty years, while higher-quality stainless-steel cylinders are covered by lifetime warranties.&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;Final analysis:&lt;/strong&gt;&lt;br /&gt;&lt;strong&gt;&lt;/strong&gt;&lt;br /&gt;I like both indirect-fired tanks and on-demand -- each one has their place. If you have a furnace and not a boiler, and use a fairly standard amount of hot water, an on-demand water heater is the way to go.&lt;br /&gt;&lt;br /&gt;If you don't have a boiler, and have exceptionally large water-heating needs (more than a typical 40-gallon water heater can provide), a high-efficiency tank-type water heater such as &lt;a href="http://www.hotwater.com/products/residential/rg-vertex100.html"&gt;A.O. Smith's Vertex &lt;/a&gt;would probably be better match for your lifestyle.&lt;br /&gt;&lt;br /&gt;If you have a fairly modern boiler, a well-made, well-insulated indirect-fired storage tank would be the best choice. In addition to the long life-expectancy, it's always safer and requires less maintenace when you minimize your combustion-appliances -- one source of combustion is better than two.&lt;br /&gt;&lt;br /&gt;So, what's better -- a tankless, on-demand water heater or an indirect-fired storage tank? It depends!&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/6743586198611027924-8755778233574603169?l=enhancedlivingblog.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://enhancedlivingblog.blogspot.com/feeds/8755778233574603169/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=6743586198611027924&amp;postID=8755778233574603169' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/6743586198611027924/posts/default/8755778233574603169'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/6743586198611027924/posts/default/8755778233574603169'/><link rel='alternate' type='text/html' href='http://enhancedlivingblog.blogspot.com/2008/07/water-heaters-on-demand-tankless-vs.html' title='Water-heaters:  On-demand tankless vs. Indirect-fired storage tanks'/><author><name>www.enhancedliving.net</name><uri>http://www.blogger.com/profile/15985241952228774254</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='19' height='32' src='http://bp1.blogger.com/_UCJi7Tzohac/SG58dAPxGkI/AAAAAAAAAAU/34fwqCcQtGQ/S220/John_CS.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-6743586198611027924.post-423640287102664853</id><published>2008-07-04T16:33:00.000-07:00</published><updated>2008-12-08T15:59:34.250-08:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='radiant floor heat'/><category scheme='http://www.blogger.com/atom/ns#' term='mixing valves'/><category scheme='http://www.blogger.com/atom/ns#' term='hydronics in-floor radiant heating'/><title type='text'>Radiant Heating 101:  Mixing valves and controls for in-floor radiant heating</title><content type='html'>A solid control apparatus is the cornerstone of a well-designed in-floor radiant heating system. The chief function of a control system is to modulate and limit water-temperatures to maximize efficiency and to insure against over-heated floors.&lt;br /&gt;&lt;br /&gt;There’s two dominant methods for controlling and modulating water-temperatures – mixing valves and injection pumps.&lt;br /&gt;&lt;br /&gt;Mixing valves come in two varieties: 3-way and 4-way mixing valves.&lt;br /&gt;&lt;br /&gt;A 3-way mixing valve has three pipe connections – hot (from the boiler), cold (from the floors) and a mix port (supply to the floors). The mix port blends hot water from the boiler with cooler water returning from the floors. This is how the mixing valve reduces the temperature of the water as it flows through the floors.&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://2.bp.blogspot.com/_UCJi7Tzohac/SG6z1Fu9kgI/AAAAAAAAAAw/YSZG9V9SjPE/s1600-h/3+way+valve+diagram.jpg"&gt;&lt;img id="BLOGGER_PHOTO_ID_5219306742822572546" style="DISPLAY: block; MARGIN: 0px auto 10px; CURSOR: pointer; TEXT-ALIGN: center" alt="" src="http://2.bp.blogspot.com/_UCJi7Tzohac/SG6z1Fu9kgI/AAAAAAAAAAw/YSZG9V9SjPE/s320/3+way+valve+diagram.jpg" border="0" /&gt;&lt;/a&gt;A 4-way mixing valve also reduces water temperatures flowing to the floors like a 3-way valve. However, at the same time, it uses one additional port to ensure that hotter water returns back to the boiler. This serves the function of protecting the boiler from “thermal shock,” which can ruin most cast-iron boilers.&lt;br /&gt;&lt;br /&gt;&lt;a onblur="try {parent.deselectBloggerImageGracefully();} catch(e) {}" href="http://2.bp.blogspot.com/_UCJi7Tzohac/SG60HcfMcoI/AAAAAAAAAA4/DUOF-ohFvNY/s1600-h/4+way+valve+diagram.jpg"&gt;&lt;img id="BLOGGER_PHOTO_ID_5219307058168099458" style="DISPLAY: block; MARGIN: 0px auto 10px; CURSOR: pointer; TEXT-ALIGN: center" alt="" src="http://2.bp.blogspot.com/_UCJi7Tzohac/SG60HcfMcoI/AAAAAAAAAA4/DUOF-ohFvNY/s320/4+way+valve+diagram.jpg" border="0" /&gt;&lt;/a&gt;A 3-way mixing valve can be used instead of a 4-way valve under the following conditions:&lt;br /&gt;&lt;br /&gt;1) When a condensing boiler constructed of stainless steel or aluminum is used. Condensing boilers do not need protection against low water temperatures, and, in fact, increase in efficiency the colder the water is.&lt;br /&gt;&lt;br /&gt;2) The system employs large-mass boiler with significant (I mean significant) water-volume. A fine example of a large-mass boiler that does not require protection from low water-temperatures is Viessmann’s Vitola 200.&lt;br /&gt;&lt;br /&gt;3) A primary-secondary piping system is employed. The primary loop, also called the “hot loop,” serves the role of protecting the boiler.&lt;br /&gt;&lt;br /&gt;4) In a two-temperature system where the proportion of “low-temperature” heating (i.e. radiant floor heat) is small relative to the “high-temperature” (i.e. baseboard convectors, radiators, etc.) zones&lt;br /&gt;&lt;br /&gt;Both 3-way and 4-way mixing valves modulate water temperatures by means of an actuator motor that hooks directly to the valve. The actuator opens and closes the valve to raise or lower the water temperatures flowing through the floors. This actuator will get its instructions via some type of electronic control device.&lt;br /&gt;&lt;br /&gt;When purchasing a “motorized” mixing valve, bear in mind that actuator motors are designed specifically for a particular mixing valve model. If you get a Honeywell mixing valve, you need the matching Honeywell actuator motor – there’s no mixing and matching among manufacturers.&lt;br /&gt;&lt;br /&gt;Furthermore, there are two dominant styles of motorized mixing valves: rotary and diverting.&lt;br /&gt;&lt;br /&gt;Diverting-type valves are the simpler and usually less expensive of the two styles, and operates like a gate valve with three positions – open, close and mix. While fully open, the water will be hot. When fully closed, the water will be cold. When in the middle (mix), they’ll do just that. When budget is a concern, or the amount of radiant floor heat is relatively small, I’ll sometimes opt for less-expensive diverting valve, such as those made by Oventrop.&lt;br /&gt;&lt;br /&gt;When the radiant load is large and I’m looking for greater accuracy in the water temperatures, a rotary valve will be utilized. A rotary valve utilizes an internal “paddle” that mixes water across a full range of temperatures. Examples include: Viessmann, DISMY (Danfoss), Rehau, Viega and Tekmar.&lt;br /&gt;&lt;br /&gt;No matter which type of mixing valve is used – and they all work reasonably well – they’re only as good as their controller. Up until fairly recently, there weren’t too many options for mixing controls. The main player was Tekmar, who still is the major supplier. In addition to producing controls under their own label, they also private-label for other manufacturers including Viega, Taco, Watts and others.&lt;br /&gt;&lt;br /&gt;Tekmar controls, such as the 360 Control, work very well in operating a mixing-valve. In addition to modulating the mixing valve, the 360 provides an outdoor boiler-reset function. If multiple mixing valves are to be used and/or you wish the control to perform other functions such as domestic hot water (with an indirect-fired storage tank), more sophisticated Tekmar controls are available. Another advantage of the Tekmar line is that they can be used with most any manufacturer’s mixing valves.&lt;br /&gt;&lt;br /&gt;As far as proprietary brands go, I find Viessmann’s HK 1M Universal mixing control useful. The control is integrated within the housing of the actuator motor, and gives the system a very sophisticated look.&lt;br /&gt;&lt;br /&gt;What I find attractive is not so much the control (which is very good), but Viessmann’s mixing valves. I find Viessmann’s 3-way and 4-way mixing valves to be among the highest quality, longest-lasting, and dead-nuts accurate. Their strength lies in their elegantly simple design.&lt;br /&gt;&lt;br /&gt;For a simple and cheap mixing valve and controller, there’s also the Taco i-Series valves. They are cost-effective solution for smaller radiant applications where super-accurate temperature-modulation isn’t required.&lt;br /&gt;&lt;br /&gt;As an alternative to mixing valves, it’s important to mention injection systems as a means of controlling water-temperatures. Instead of using a mixing valve, injection systems use a variable speed circulator pump to “inject” hot water from the boiler into the radiant system.&lt;br /&gt;&lt;br /&gt;Injection systems do work well, however they require the use of many additional (unnecessary) pumps – at least three, but usually more -- in order to function.&lt;br /&gt;&lt;br /&gt;Injection systems require the designer to employ primary-secondary piping. This means you have a primary pump on the boiler, a secondary pump for the main distribution loop, and typically, additional zone pumps. The actual injection pump itself sits between the primary and secondary loop. Too much for an otherwise simple job, in my opinion. As you would expect, an engineer developed this type of system!&lt;br /&gt;&lt;br /&gt;As much as poo-poo injection, there are rare instances where this is the smarter, simpler option. These instances are very rare and usually only occur in larger commercial applications or huge McMansions where the system becomes very sophisticated -- not in basic residential jobs.&lt;br /&gt;&lt;br /&gt;If you do choose to go with injection, you’ll need a controller just like you would with a mixing valve. Again, Tekmar is the primary player for these controls.&lt;br /&gt;&lt;br /&gt;Finally, it is very common for many contractors, and especially DIY’ers, to substitute a modulating motorized mixing valve with a cheap thermostatic or fixed mixing valve intended for water-heating.&lt;br /&gt;&lt;br /&gt;In many applications, it gets the job done, and on a few occasions, have done it myself. While it does serve the function of limiting outgoing supply-water temperatures, it doesn’t modulate, nor does it add any energy-efficiency benefits that a motorized valve brings to the table. Where it works is on a small, isolated radiant loop - when you’re trying to put some heat under a bathroom floor, for example.&lt;br /&gt;&lt;br /&gt;I wouldn’t use a cheap fixed mixing valve to do an entire house. Nor would I use one when heating a concrete slab. Concrete slabs hold a tremendous amount of mass. They take a long time to heat up, but more critically, they take just as long to cool off if they become overheated. In my view, modulating mixing valves on an outdoor-reset are a must for slab applications.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/6743586198611027924-423640287102664853?l=enhancedlivingblog.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://enhancedlivingblog.blogspot.com/feeds/423640287102664853/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=6743586198611027924&amp;postID=423640287102664853' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/6743586198611027924/posts/default/423640287102664853'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/6743586198611027924/posts/default/423640287102664853'/><link rel='alternate' type='text/html' href='http://enhancedlivingblog.blogspot.com/2008/07/solid-control-apparatus-is-cornerstone.html' title='Radiant Heating 101:  Mixing valves and controls for in-floor radiant heating'/><author><name>www.enhancedliving.net</name><uri>http://www.blogger.com/profile/15985241952228774254</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='19' height='32' src='http://bp1.blogger.com/_UCJi7Tzohac/SG58dAPxGkI/AAAAAAAAAAU/34fwqCcQtGQ/S220/John_CS.jpg'/></author><media:thumbnail xmlns:media='http://search.yahoo.com/mrss/' url='http://2.bp.blogspot.com/_UCJi7Tzohac/SG6z1Fu9kgI/AAAAAAAAAAw/YSZG9V9SjPE/s72-c/3+way+valve+diagram.jpg' height='72' width='72'/><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-6743586198611027924.post-216089494250865963</id><published>2008-07-04T04:57:00.001-07:00</published><updated>2008-07-27T10:43:42.827-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='hydronic radiant heat'/><category scheme='http://www.blogger.com/atom/ns#' term='in floor radiant heating'/><title type='text'>Is in-floor radiant heat efficient?</title><content type='html'>The answer to whether radiant heat is efficient is yes and no. Radiant floor-heating is nothing but a form of radiator.&lt;br /&gt;&lt;br /&gt;Instead of using finned-baseboard, cast-iron floor radiators or flat-panel wall radiators, you're using tubing on or below the floor as the source of heat-radiation. And like any of the other radiator options, it can be designed and installed efficiently or it can be made to run like a hog.&lt;br /&gt;&lt;br /&gt;Several factors can make or break the efficiency of your radiant heating system.&lt;br /&gt;&lt;br /&gt;&lt;span style="FONT-WEIGHT: bold"&gt;1) Insulate under the floor&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;Unlike a forced-air heating system, which causes warm air to rise, radiant heating radiates in any and every direction. Moreover, due to the laws of thermodynamics, the heat emitted from the tubing will want to go towards the coldest path. If that path happens to be down (toward a cold basement, perhaps), that's where the heat will go.&lt;br /&gt;&lt;br /&gt;The better you insulate below the floor, the more efficient the system will be at delivering heat into the room in which it was intended. Most manufacturers recommend a minimum of R-13 (about 4" of fiberglass). Don't rely on thin &lt;span class="blsp-spelling-error" id="SPELLING_ERROR_0"&gt;Astro&lt;/span&gt;-Foil (the stuff with bubbles) to do the job, as many people make the mistake of doing.&lt;span style="FONT-WEIGHT: bold"&gt;&lt;br /&gt;&lt;/span&gt;&lt;br /&gt;One can reasonably argue that radiant floor-heating is less efficient than radiators installed within the room. If the radiators are over-sized, like many old cast-iron radiators are, this is true, since there are no downward heat losses associated with radiators. &lt;span style="FONT-WEIGHT: bold"&gt;&lt;span style="FONT-WEIGHT: bold"&gt;&lt;span style="FONT-WEIGHT: bold"&gt;&lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;/span&gt;&lt;span style="FONT-WEIGHT: bold"&gt;2) Minimize water temperatures&lt;/span&gt;&lt;span style="FONT-WEIGHT: bold"&gt;&lt;br /&gt;&lt;/span&gt;&lt;br /&gt;A well-designed radiant floor heating system should never exceed water-temperatures of (approx.) 135 degrees (F). The lower your water temperature, the more efficient the system will be. In many cases, it's possible to operate a system with maximum water-temperatures of 110-115 degrees (F). You can accomplish this by installing tubing at closer spacing (6" &lt;span class="blsp-spelling-error" id="SPELLING_ERROR_1"&gt;OC&lt;/span&gt; versus 9" or 12").&lt;br /&gt;&lt;br /&gt;&lt;span style="FONT-WEIGHT: bold"&gt;3) Utilize a modulating control system&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;When we talk about a system's design-temperature, we're talking about the water-temperature needed to heat the home on the coldest day of the year. The rest of the time we can run the system at a lower supply-water temperature.&lt;br /&gt;&lt;br /&gt;This can be accomplished automatically with a modulating control system that utilizes a boiler-reset control (w/ either an indoor and/or outdoor temperature sensor), and a modulating mixing-valve or variable-speed injection pump. I prefer mixing-valves over injection pumps, as mixing valves require just one pump versus three (primary loop pump + injection pump + secondary loop pump) for an injection system. That said, both methods modulate water temperatures based on outdoor and/or indoor temperatures. Lower water temperatures mean higher efficiency.&lt;br /&gt;&lt;br /&gt;&lt;span style="FONT-WEIGHT: bold"&gt;4) Use the right boiler&lt;br /&gt;&lt;span style="FONT-WEIGHT: bold"&gt;&lt;span style="FONT-WEIGHT: bold"&gt;&lt;span style="FONT-WEIGHT: bold"&gt;&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;When shooting for efficiency, the standard boiler has become wall-hung condensing models&lt;span style="FONT-WEIGHT: bold"&gt;. &lt;/span&gt;Condensing boilers often reach efficiencies of up to 95-96 percent. Sophisticated models often have built-in outdoor-reset controls and fully modulating burners to minimize water-temperatures and maximize combustion-efficiency. &lt;span class="blsp-spelling-corrected" id="SPELLING_ERROR_2"&gt;Condensing&lt;/span&gt; boilers run the &lt;span class="blsp-spelling-corrected" id="SPELLING_ERROR_3"&gt;gamut&lt;/span&gt; in terms of price and quality. Like anything else, you really get what you pay for -- and it pays to pay more. Look for models with stainless-steel heat-exchangers (avoid aluminum or copper) and fully modulating burners (versus one or two stage). &lt;span style="FONT-WEIGHT: bold"&gt;&lt;/span&gt;&lt;span style="FONT-WEIGHT: bold"&gt;&lt;span style="FONT-WEIGHT: bold"&gt;&lt;span style="FONT-WEIGHT: bold"&gt;&lt;span style="FONT-WEIGHT: bold"&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br /&gt;&lt;span style="FONT-WEIGHT: bold"&gt;&lt;span style="FONT-WEIGHT: bold"&gt;&lt;/span&gt;&lt;/span&gt;&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/6743586198611027924-216089494250865963?l=enhancedlivingblog.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://enhancedlivingblog.blogspot.com/feeds/216089494250865963/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=6743586198611027924&amp;postID=216089494250865963' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/6743586198611027924/posts/default/216089494250865963'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/6743586198611027924/posts/default/216089494250865963'/><link rel='alternate' type='text/html' href='http://enhancedlivingblog.blogspot.com/2008/07/is-in-floor-radiant-heat-efficient.html' title='Is in-floor radiant heat efficient?'/><author><name>www.enhancedliving.net</name><uri>http://www.blogger.com/profile/15985241952228774254</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='19' height='32' src='http://bp1.blogger.com/_UCJi7Tzohac/SG58dAPxGkI/AAAAAAAAAAU/34fwqCcQtGQ/S220/John_CS.jpg'/></author><thr:total>0</thr:total></entry><entry><id>tag:blogger.com,1999:blog-6743586198611027924.post-3659927234408089091</id><published>2008-06-29T09:32:00.000-07:00</published><updated>2008-07-27T08:57:12.212-07:00</updated><category scheme='http://www.blogger.com/atom/ns#' term='dual fuel heating system'/><category scheme='http://www.blogger.com/atom/ns#' term='heat pump'/><title type='text'>A heat pump revival in the Northeast</title><content type='html'>Traditionally, standard air-to-air heat pumps have been a dirty word in the Northeast. High electricity rates and poor performance at low outdoor temperatures have made new installations of air-source heat pumps an almost taboo practice. But several factors have caused contractors (including us) to take another look at air-to-air heat pumps.&lt;br /&gt;&lt;br /&gt;The biggest knock against air-source heat pumps is the fact that their heat-output drops substantially once the outdoor temperatures gets below approx. 30 degrees F. Below 30 degrees or so, a secondary heat source must be utilized. Traditionally, this secondary heat source has been electric strip-heaters -- very expensive to operate -- and hence the unpopularity of air-to-air heat pumps.&lt;br /&gt;&lt;br /&gt;Now that heating oil has broken the $5.00 / gallon barrier, heat pumps have gotten a second look. By utilizing heat pumps in a dual-fuel heating strategy, we can use them where they work best -- at temperatures above 30 degrees -- and utilize heating oil or propane as the secondary fuel instead of electric strip-heaters.&lt;br /&gt;&lt;br /&gt;Above 30 degrees F, air-source heat pumps work exceptionally well in terms of cost-efficiency. Moreover, more than two-thirds of our heating season (upstate NY) is spent at temperatures &lt;span style="FONT-STYLE: italic"&gt;above&lt;/span&gt; 30 degrees F. For the remaining one-third of the season, we can switch over to oil or propane.&lt;br /&gt;&lt;br /&gt;This "dual-fuel heating" option results in an operational cost-savings of 30 to 40 percent over typical oil-fired equipment.&lt;br /&gt;&lt;br /&gt;To make the switch-over from heat pump to fossil-fuel furnace (or boiler) automatic, one can use a traditional two-stage heat pump thermostat, or go one step further with a specialized control, such as the &lt;a href="http://www.theheatpumpmadeeasy.com/"&gt;Bill Porter Dual Fuel Kit&lt;/a&gt;.&lt;br /&gt;&lt;br /&gt;Another factor making heat pumps more attractive in the Northeast is the increasing trend toward "cold-climate" heat pumps. A small handful of manufacturers have developed air-source heat pumps capable of operating at sub-zero temperatures. Manufacturers of cold-climate heat pumps include &lt;a href="http://www.gotohallowell.com/index.php"&gt;Hallowell International &lt;/a&gt;and &lt;a href="http://www.mrslim.com/"&gt;Mitsubishi Electric .&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;Cold-climate heat-pumps are capable of carrying the entire heat-load of the home at temperatures as low as -14 F degrees, rarely needing a secondary heat-source.&lt;br /&gt;&lt;br /&gt;Heat pumps are one of the most cost-effective upgrades one can make if they are currently using heating oil or propane as their primary fuel.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/6743586198611027924-3659927234408089091?l=enhancedlivingblog.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='replies' type='application/atom+xml' href='http://enhancedlivingblog.blogspot.com/feeds/3659927234408089091/comments/default' title='Post Comments'/><link rel='replies' type='text/html' href='http://www.blogger.com/comment.g?blogID=6743586198611027924&amp;postID=3659927234408089091' title='0 Comments'/><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/6743586198611027924/posts/default/3659927234408089091'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/6743586198611027924/posts/default/3659927234408089091'/><link rel='alternate' type='text/html' href='http://enhancedlivingblog.blogspot.com/2008/06/heat-pump-revival-in-northeast.html' title='A heat pump revival in the Northeast'/><author><name>www.enhancedliving.net</name><uri>http://www.blogger.com/profile/15985241952228774254</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='19' height='32' src='http://bp1.blogger.com/_UCJi7Tzohac/SG58dAPxGkI/AAAAAAAAAAU/34fwqCcQtGQ/S220/John_CS.jpg'/></author><thr:total>0</thr:total></entry></feed>
